File information: | |
File name: | Preventive Maintenance Test with Insulation Resistance Test - Application Note 5991-4026EN c20141010 [preview Preventive Maintenance Test with Insulation Resistance Test - Application Note 5991-4026EN c20141010] |
Size: | 376 kB |
Extension: | |
Mfg: | Agilent |
Model: | Preventive Maintenance Test with Insulation Resistance Test - Application Note 5991-4026EN c20141010 🔎 |
Original: | Preventive Maintenance Test with Insulation Resistance Test - Application Note 5991-4026EN c20141010 🔎 |
Descr: | Agilent Preventive Maintenance Test with Insulation Resistance Test - Application Note 5991-4026EN c20141010 [9].pdf |
Group: | Electronics > Other |
Uploaded: | 04-12-2021 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name Preventive Maintenance Test with Insulation Resistance Test - Application Note 5991-4026EN c20141010 Keysight Technologies Preventive Maintenance Test with Insulation Resistance Test Application Note Introduction Preventive maintenance is a predetermined task performed based on a schedule and its objective is to keep equipment in good condition to avoid breakdowns. Insulation resistance testing is commonly performed as part of electrical testing in a preventive maintenance program for rotating machines, cables, switches, transformers, and electrical machinery where insulating integrity is needed. Insulation resistance testing in the preventive maintenance pro- gram helps identify potential electrical issues to reduce unpredictable, premature equipment repairs and replacement costs. With properly scheduled monitoring and data collection, this testing can be very useful in analyzing and predicting the current and future behavior of equipment. Early problem detection helps avoid major repairs, resulting in cost savings when compared to a run-to-failure maintenance practice. Preventive maintenance has the added benefit of allowing time to order any necessary parts and schedule appropriate resources. This application note describes the insulation resistance testing method used for preventive maintenance activities. 2 What is Insulation Resistance Testing? Insulation resistance testing is carried out by applying a constant voltage to the equipment under test while measuring the any flowing current. High DC voltages are used causing a small current to flow through the insulator surface. The total current consists of three components: capacitance charging current, absorption current, and leakage current (refer to Figure 1.) |
Date | User | Rating | Comment |